Electromagnetic Locks

Electromagnetic Locks

Proven Fail-Safe Locking from 60 kg to 500 kg Holding Force

ISO 9001 Fail-Safe LED Feedback Anti-Residual Ex-Proof Available

Over 40 model variants from our ISO-certified manufacturing partner. No moving parts, instant release, and fail-safe by design. Surface-mount, recessed, concealed, single-door and double-door configurations. Explosion-proof models (Ex ib IIC T6 Gb, IP66) for hazardous environments.

  • 60 kg to 500 kg holding force (5 series: DZM01/DZ02/DZ03/DZ04/DZ05)
  • LED status indicator (red = locked, green = unlocked)
  • Signal feedback output (dry contact) for access control integration
  • Adjustable timer delay (0–15 seconds, X-type models)
  • Anti-residual magnetism for instant release on power cut
  • Explosion-proof models — Ex ib IIC T6 Gb · IP66 · Zone 1 & 2
  • Operating temperature: -40°C to +70°C
ISO 9001:2015
ISO 14001:2015
ISO 45001:2018
ISO-certified manufacturer
30+ Years Manufacturing

Product Range

Complete Model Specifications

Model naming: DZ = Electromagnetic Lock · 02=150kg, 03=280kg, 04=350kg, 05=500kg · G=Surface mount, Q=Recessed · C=LED indicator, X=LED + timer + feedback, Y=LED + feedback · S=Double door

ModelDZM01G DZ02G
DZ02Q
DZ03GC
DZ03QC
DZ03GX
DZ03QX
DZ03GY
DZ03QY
DZ04GC
DZ04QC
DZ04GX
DZ04QX
DZ04GY
DZ04QY
DZ05GC
DZ05QC
DZ05GX
DZ05QX
DZ05GY
DZ05QY
VoltageDC12VDC12VDC12VDC12–24VDC12VDC12VDC12VDC12VDC12VDC12–24VDC12V
Current120mA300mA300mA300mA300mA300mA300mA300mA300mA300mA300mA
Power1.5W3.6W3.6W3.6W3.6W3.6W3.6W3.6W3.6W3.6W3.6W
Holding Force60kg150kg280kg280kg280kg350kg350kg350kg500kg500kg500kg
Signal Feedback———YesYes—YesYes—YesYes
Timer Delay———Yes——Yes——Yes—

Note: Double-door (S) models have the same electrical specs as single-door models (except voltage). Physical dimensions are doubled.

Standard Models

DZ02 150kg Electromagnetic Lock — Front View | HowLock

DZ02 — 150 kg

DC12V · 300mA · 3.6W
Body: 200.8 × 35 × 23.5 mm

Get Quote
DZ03 280kg Electromagnetic Lock — Surface Mount | HowLock

DZ03 — 280 kg

DC12V · 280mA · 3.6W
Body: 241 × 52 × 28 mm
LED + Signal Feedback

Most Popular Get Quote
DZ04 350kg Electromagnetic Lock — Surface Mount | HowLock

DZ04 — 350 kg

DC12V · 290mA · 3.6W
Body: 271 × 52 × 26.5 mm
LED + Signal Feedback

Get Quote
DZ05 500kg Electromagnetic Lock — Heavy Duty | HowLock

DZ05 — 500 kg

DC12V · 300mA · 3.6W
Body: 264 × 70 × 38.5 mm
LED + Timer + Signal Feedback

Get Quote

Mounting Variants

DZ03GC 280kg Concealed Electromagnetic Lock — Flush Mount | HowLock

Concealed Mount (C-Type)

DZ03GC · 280kg
Body: 281 × 47 × 26.5 mm
Armature: 158 × 45 × 13 mm
Clean concealed appearance for premium interiors

DZ02GX 150kg Recessed Electromagnetic Lock — Timer + Feedback | HowLock

Recessed Mount (X-Type)

Timer + LED + Signal Feedback
Flush-mount into door frame
Available in all force ratings

DZ03GYS 280kg Double-Door Electromagnetic Lock — Surface Mount | HowLock

Double Door (S-Type)

DZ03GYS · 280kg × 2
Same electrical specs as single-door
Doubled physical dimensions

Explosion-Proof Models (Ex ib IIC T6 Gb · IP66)

ModelDZ02FG
DZ02FQ
DZ02FGS
DZ02FQS
DZ03FG
DZ03FQ
DZ03FGS
DZ03FQS
DZ04FG
DZ04FQ
DZ04FGS
DZ04FQS
DZ05FG
DZ05FQS
DZ05FGS
DZ05FQS
VoltageDC12VDC12VDC12VDC12VDC12VDC12VDC12VDC12V
Current300mA600mA300mA600mA300mA600mA300mA600mA
Power3.6W7.2W3.6W7.2W3.6W7.2W3.6W7.2W
Holding Force150kg150kg×2280kg280kg×2350kg350kg×2500kg500kg×2

Explosion-proof marking: Ex ib IIC T6 Gb · Protection class: IP66 · Operating temperature: -20°C to +40°C · Suitable for Zone 1 & Zone 2 hazardous areas (IIA, IIB, IIC gas groups, T1–T6 temperature classes).
Applications: Petrochemical plants, oil rigs, gas stations, steel mills, pharmaceutical plants, military installations.

Key Features

LED Status Indicator

Red = locked, Green = unlocked. Visible from a distance for quick security patrols and system verification.

Signal Feedback Output

Dry contact reports lock status. Confirms armature seating, triggers alarms for held-open or forced doors.

Adjustable Timer Delay

0-15 seconds configurable hold-open time. Eliminates external timer relays and reduces wiring complexity.

Anti-Residual Magnetism

Precision-engineered core ensures door releases immediately when power is cut. Critical for emergency egress compliance.

Fail-Safe Operation

Power on = locked, Power off = unlocked. Automatically releases during power failure or fire alarm activation.

Explosion-Proof Models

Flame-proof enclosure (Ex d), sealed cable glands, corrosion-resistant housing. Zone 1 and Zone 2 certified.

Detailed Specifications by Model

DZM01G — 60 kg Surface-Mount

Holding Force60 kg
Operating VoltageDC 12V
Current Draw≤120 mA
Body Dimensions80 × 37 × 25.5 mm
Armature Plate70 × 31 × 11 mm
FeaturesBuilt-in surge absorber

DZ02 Series — 150 kg

Holding Force150 kg
Operating VoltageDC 12V (GX: DC 12–24V)
Current Draw≤260 mA
Body (Surface G)165.8 × 40 × 23.5 mm
Body (Recessed Q)200.8 × 35 × 23.5 mm
Armature Plate135 × 31 × 11 mm
Operating Temperature-40°C to +70°C

Available variants:

  • DZ02G / DZ02Q — Basic (no feedback)
  • DZ02GS / DZ02QS — Basic double-door
  • DZ02GX / DZ02QX — LED + Timer + Signal feedback

DZ03 Series — 280 kg (Most Popular)

Holding Force280 kg (600 lbs)
Operating VoltageDC 12V (GX: DC 12–24V)
Current Draw≤280 mA
Body (Surface GY)241 × 52 × 28 mm
Body (Concealed GC)281 × 47 × 26.5 mm
Body (Recessed GX)241 × 52 × 28 mm
Armature Plate158 × 45 × 13 mm
LED IndicatorYes (C/X/Y models)
Signal FeedbackYes (X/Y models) — Dry contact
Timer DelayYes (X models) — Adjustable
Anti-Residual MagnetismYes

Available variants:

  • DZ03GC / DZ03QC — LED indicator only
  • DZ03GX / DZ03QX — LED + Timer + Signal feedback
  • DZ03GY / DZ03QY — LED + Signal feedback
  • DZ03GCS / DZ03GYS / DZ03GXS — Double-door versions

Voltage tolerance: ±10% operating range

DZ04 Series — 350 kg

Holding Force350 kg (750 lbs)
Operating VoltageDC 12V
Current Draw≤290 mA
Body (Surface GCS)271 × 52 × 26.5 mm
Body (Recessed QC)311 × 47 × 26.5 mm
Armature Plate180 × 45 × 13 mm
VariantsGC/GX/GY/QC/QX/QY + double-door S versions

DZ05 Series — 500 kg

Holding Force500 kg (1100 lbs)
Operating VoltageDC 12V (GX: DC 12–24V)
Current Draw≤300 mA
Body (Surface GXS)264 × 70 × 38.5 mm
Body (Recessed QXS)314 × 65 × 36.8 mm
Armature Plate175 × 62 × 13 mm
FeaturesLED + Timer + Signal feedback (X models)
Quality SystemISO 9001:2015 · ISO 14001:2015 · ISO 45001:2018

Mounting Options

Surface Mount (Standard)

Lock body on frame, armature on door. Most common installation for commercial and institutional doors.

Shear Lock (Flush Mount)

Recessed into frame and door leaf. Clean, concealed appearance for architectural glass doors and premium interiors.

Z-Bracket & L-Bracket

For inward/outward-opening doors, deep recesses, and non-standard frame profiles. Full bracket kits available.

Brackets & Accessories

AccessoryCompatible ModelsDoor TypeNotes
U-Bracket (Glass Door Clamp)150kg, 280kg maglocksFrameless glass doorsGlass thickness: 8–15 mm
L & Z Bracket150kg, 280kg, 350kg, 500kgInward/outward-opening doorsWeight: 0.4–1.4 kg depending on maglock size

Control Boxes

KZH1A / KZH1B — Keypad Control Box

DC 12–24V · ≤470mA · Password delay: 2, 4, 6, 9 sec · Lock status feedback · Optional IC card reader · For wooden, metal, and fire-rated doors

KZH2 — Compact Control Box

DC 12–24V · ≤500mA · Password delay: 2, 4, 6, 9 sec · Lock status feedback · IC card dedicated · Weight: 0.5 kg · 24 pcs/carton

KZH3 — Embedded Control Box

DC 12V · ≤470mA · Adjustable delay: 5–15 sec · Signal feedback · For access control systems · Push-button & key operation

Applications

280kg Electromagnetic Lock for Glass Door Installation | HowLock

Glass Door Installations

Compact 180 kg model suits frameless and framed glass doors. Specialized U-brackets accommodate various glass thicknesses.

Commercial Buildings

280 kg maglocks for office entrances and corridor doors. Signal feedback integration provides real-time monitoring.

Fire Exit Doors

500 kg model with automatic release upon fire alarm activation. Anti-residual magnetism guarantees immediate door opening.

Industrial & Hazardous

Explosion-proof models for petrochemical plants, LNG facilities, and chemical storage. Heavy-duty 500 kg for perimeter gates.

Server Rooms & Data Centers

Signal feedback for monitoring. Timer delay prevents doors remaining unlocked after authorized entry.

Frequently Asked Questions

Electromagnetic locks are fail-safe — they unlock when power is removed. Suitable for emergency exits and fire-rated doors. For fail-secure (locked when power is removed), consider our electric bolt locks.

180 kg for lightweight interior doors, 280 kg for standard commercial doors, 350 kg for heavy doors, and 500 kg for high-security applications. When in doubt, choose the next size up.

Yes. The 180 kg and 280 kg models work on frameless and framed glass doors using specialized U-brackets and glass-door mounting kits.

Yes. Maglocks are passive devices controlled by cutting power. Any access controller, timer, or switch that interrupts 12V/24V DC can operate these locks. No proprietary protocols involved.

No moving parts means minimal maintenance. Periodic cleaning of armature plate contact surface and checking mounting hardware and wiring connections annually is recommended.

Ready to Order?

Tell us the holding force, mounting type, quantity, and whether you need standard or explosion-proof. We respond within 24 hours.